Engtips.

(RTTNews) - Himax Technologies, Inc. (HIMX) reported that its second quarter profit to stockholders declined to $70.64 million from $108.89 millio... (RTTNews) - Himax Technologies...

Engtips. Things To Know About Engtips.

Strut-Tie Model - Exterior Joint. Under the section of Geometry of the STM and Forces, he states the column moment is half the nominal beam moment. No end conditions are given for either the beam or the column, so I am lead to believe that simple moment equilibrium about the intersecting centre would result in the column moment …Foundation engineering. (26096 members) forum256 - Professional forum and technical support for engineers for Foundation engineering. Includes problem solving collaboration tools. Forum. Search.Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for Computers and Structures: SAFE. Includes problem solving collaboration tools. Finite Element Analysis (FEA) engineering. (36618 members) forum727 - Professional forum and technical support for engineers for Finite Element Analysis (FEA) engineering. Includes problem solving collaboration tools. Forum.

PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book.

Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: SOLIDWORKS 3D Design. Includes problem solving collaboration tools. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ...

Wind load on the superstructure may be calculated as. 150 psf x A x L. Where 150 psf is the wind pressure (Check also your state or local requirements for different criteria), A is the area of the superstructure in elevation (Curb height, slab height, haunch height, girder and any superelevation), and L is the tributary length … Bridge engineering. (7015 members) forum607 - Professional forum and technical support for engineers for Bridge engineering. Includes problem solving collaboration tools. Search. Eng-Tips aims to support students’ professional and academic development. Engineering information and connections for the global community of engineers. Find engineering …The current ASME VIII require you to obtain U stamp certification from the ASME Board. They will issue to you, based on extensive testing of your design and fabrication capability, experience and understanding of the current ASME code requirements. No specific PD 5500 requirements. Please note that this month is …

To Remove or insert a Spacer or Blind you first depressurize the System, Then make it Safe. Then you remove all the Bolts on One (1) side of the Flange set. Then you "Jack" the Flanges apart using the built-In Jack Screws (in the Flanges) or with Flange Spreaders (Look it up). Now with the Flanges spread …

Analyze the purlin as a beam with fixed ends and design your connection for that moment with a healthy amount of extra capacity. I am using the current code required snow loads. In my area, the required snow load is 35psf, so I am not overly worried about wind. JStructsteel (Structural) 1 Nov 22 12:45.

Specifically, bollards for protection are angled toward the direction of the expected threat; this provides an added measure of strength, since there's no reason to make the bollards be symmetrical in protection direction/angle. Angling the bollard could reduce the required thickness of the bollard, since the collision energy is directed ...Eng-Tips aims to support students’ professional and academic development. Eng-Tips is a forum for engineering professionals and students of all disciplines. (Stock photo.)SIG:Please see FAQ731-376: Eng-Tips.com Forum Policies for tips on how to make the best use of Eng-Tips. RE: "Break sharp edges" note. berkshire (Aeronautics) 26 Feb 09 19:32. The most common tool for breaking sharp edges in the aircraft industry is a small tool called a Burr Wik, it has a receptacle into which several types of scraper like … Activities. Civil/Environmental engineering general discussion. Climate Change Engineering Solutions. Earthwork/grading engineering. Soil/Groundwater environmental engineering. Storm/Flood engineering. Surveying & Geomatics. Traffic Engineering. Waste disposal & treatment. As a foundry engineer in a Aluminnum foundry we fight this with customers all the time. #1- Aluminum has roughly 1/2 the Brinell of iron ( hardness) thiss means if you used 6 - 3/8X16 x 1 bolts on a iron part you better look at. using 10 1/2 x 13 x 1.5 in aluminum. We also push Heli coils.

Deflections under seismic loading - Part 2. It's my understanding that 4.1.8.11.3) d) v) allows us to use a larger period specifically to check seismic deflections. This means I'll have a different base shear than my regular elastic analysis, so I always run a distinct case anyways.From raising minimum wages to "staple green cards." The allocation of H-1B visas is very inefficient, with the lottery system being used in the years with the greatest visa demand—...Mar 2, 2021 · Collaborate with other engineers! Their input will help you overcome mental hurdles and refine your designs. Plus, brainstorming with others is an excellent way to uncover innovative solutions to long-standing engineering issues. A great online resource is eng-tips.com. #13 Over-communicate Stay connected with all the key players in a project. *Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home > Forum Areas Chemical Engineers Area. Only the top forums under each heading is …1) Perforated. There are code restrictions on why you can use this. It is generally less expensive than the FTAO (Force Transfer Around Openings) method because it does not require you to use straps around all the openings. 2) FTAO: To me, this method is merely a "rational" method.Safety Relief Valve engineering (PSV) (8433 members) forum1203 - Professional forum and technical support for engineers for Safety Relief Valve engineering (PSV). Includes problem solving collaboration tools. Forum.

Will and Mango from Part-Time Genius explore the subject of rudeness — why it's dangerous to our health and why we can't stop thinking about it. Advertisement Someone cuts you off ...

We have piles (300 dia, between 2m and 3m deep) embedded in a mixture of cohesive and granular soils. Su in cohesive range between 70kPa to 150kPa. DCP readings of between 2 & 3 in granular (50mm increments). We are doing pullout test at construction stage to confirm but want an estimate for design …Men's Health offers eighteen tricks that make a body feel better, like how to clear a stuffed nose or make an injection hurt less. Men's Health offers eighteen tricks that make a b...Will and Mango from Part-Time Genius explore the subject of rudeness — why it's dangerous to our health and why we can't stop thinking about it. Advertisement Someone cuts you off ...smokiibear (Civil/Environmental) (OP) 10 Jan 20 17:08. I'm refering to the specific wording in 7-16, chp 28. Also, I have two structures that will combine to make 1. When the roof is off, I have walls with no roof, and I have a roof with no walls. The roof will slide to another structure without walls, just columns.Shear walls3. I was reading reinforced concrete mechanics by MacGregor about shear walls. The book says that a possible solution to decrease foundation size is to " Attach the base of the wall to the ground-floor diaphragm and basement floor to provide a horizontal force couple to react to the moment at the …Joel - I tried to configure (imagine) a non-prestressed concrete tank that had H^2 / Dt > 50. Hard to do. For both the considerations of the combined shear + flexural demand at the base, and shrinkage, tall non-prestressed concrete tanks are uncommon, and I certainly would try to persuade you toward either steel or prestressed (DYK / DN) Type …Note that if you select either pinned or fixed, you are departing from reality already, as the connection is unlikely to fit either exactly. So it could be modeled as intermediate in various ways as well. If you neglect deflections in the roof unrelated to this load, you are departing from reality. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Join Eng-Tips Forums! Talk With Other Members; Be Notified Of Responses To Your Posts; Keyword Search; One-Click Access To Your Favorite Forums; Automated Signatures On Your Posts; Best Of All, It's Free! Join Us! *Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting …Section 9 (of the 14th edition manual) has a section on coped beam strength. But, it does't talk about the detailing of that cope at all (i.e. rounded vs square). It also has a section on Copes, Blocks and Cuts which talks about the preferred method of sequencing the coping cuts. But, it doesn't talk much about …

Each pipe weighs approx 50kg. They're stacked on top of each other. Now if this container held soil or water the loads to the uprights would be easy to calculate but in this case I'm unsure how to proceed. Obviously if the supports were t0 be removed the pipe stack would collapse. It follows that there is a horizontal component of the load at ...

SIG:Please see FAQ731-376: Eng-Tips.com Forum Policies for tips on how to make the best use of Eng-Tips. RE: "Break sharp edges" note. berkshire (Aeronautics) 26 Feb 09 19:32. The most common tool for breaking sharp edges in the aircraft industry is a small tool called a Burr Wik, it has a receptacle into which several types of scraper like …

Electric motors & generators engineering. (55332 members) forum237 - Professional forum and technical support for engineers for Electric motors & generators engineering. Includes problem solving collaboration tools. The answer can be found in a textbook or your lecture notes from school. Shear design formulas in EC2 are based on strut-and-tie models, and when the distance of the critical section is "d" or less than that, a large part of the shear is transferred by arch action (a compression strut) directly to the support.Indian women are more educated than they have ever been. Yet, the latest figures show that fewer of them are working. Indian women are more educated than they have ever been. Yet, ...One of the restrictions is to limit the the bead width to 4x core wire diameter. SJones (Petroleum) 3 Jul 08 13:40. Indeed it is: in item (f), 4, a). My apologies for missing this very specific case since it is adopted as the norm for all our vessel and piping SMAW welding. Steve Jones. Materials & Corrosion Engineer.One of the restrictions is to limit the the bead width to 4x core wire diameter. SJones (Petroleum) 3 Jul 08 13:40. Indeed it is: in item (f), 4, a). My apologies for missing this very specific case since it is adopted as the norm for all our vessel and piping SMAW welding. Steve Jones. Materials & Corrosion Engineer. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Strut-Tie Model - Exterior Joint. Under the section of Geometry of the STM and Forces, he states the column moment is half the nominal beam moment. No end conditions are given for either the beam or the column, so I am lead to believe that simple moment equilibrium about the intersecting centre would result in the column moment …Existing 2 storey 40+ yr old house all walls as 4" brick exterior with 4" block backup, with bond bricks turned every 7th course. I believe that this is considered as an 8" masonry bearing wall...not 4" load bearing block with 4" veneer. The building depts around are extremely quick to call out 'brick veneer' can't be used for connecting or ...Student posting in Eng-Tips forums for help with theses or coursework is forbidden. This is considered cheating. Offending posts will be removed from the site and offending members will lose their membership privileges. Posting. Commercial and/or recruiting "spam" will not be tolerated in the forums. Our forums are member-policed via the forums' "Red-Flag" … Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Eng-Tips aims to support students’ professional and academic development. Eng-Tips is a forum for engineering professionals and students of all disciplines. (Stock photo.)i have got into trouble with linear gap element. My model like flange contact have 500000 dof. i use linear gap method in axial direction and rbe2 (Fy~Mz) in other direction. unfurtunately, i just obtain some fatal message "fatal message 1012" no matter what i do. (try to change buffsize) or wirte down "nastran system (1015)=1".

Just one little thing to type or bookmark, and you'll have a fresh document in front of you. “I’m always doing some terrible workaround to try to get to Docs quickly,” our Senior T...Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register …Indian women are more educated than they have ever been. Yet, the latest figures show that fewer of them are working. Indian women are more educated than they have ever been. Yet, ...woman with red coat walking up the stairs to the clouded sky Cancer Matters Perspectives from those who live it every day. Your email address will not be published. Required fields...Instagram:https://instagram. lilith blue 98 onlyfansticketmaster taylor swift vancouversleep music youtube 1 hourseekingalpha nvda Shear walls3. I was reading reinforced concrete mechanics by MacGregor about shear walls. The book says that a possible solution to decrease foundation size is to " Attach the base of the wall to the ground-floor diaphragm and basement floor to provide a horizontal force couple to react to the moment at the … secrets gifcoffee in some martinis crossword clue Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: SOLIDWORKS 3D Design. Includes problem solving collaboration tools. rebecca night nude You mean we can directly draw a cantilever beam with one end attached to a beam or column while the other end attached to nothing? The beam end is default to be fixed or pinned? slickdeals (Structural) 4 Nov 08 08:11. In ETABS, things are fixed by default unless specified explicitly to be pinned.